Molecular Diagnostics  Oligonucleotides Synthesis  Capillary Sequencing  Next-Generation Sequencing  Bioinformatics Analysis 

There are numbers of sexual transmitted diseases caused by various bacteria and virus namely Chlamydia trachomatis, Neisseria gonorrhea and HIV. The conventional detection method involves viral and bacterial culture, serology test and enzyme-linked immuno assay (ELISA) which are labour-intensive and time consuming. A rapid and precise detection assay is therefore crucial for determination of the infectious pathogen in various samples such as blood, vesicles and pus for effective management of patients. AITbiotech's solution using real-time PCR technology offers unsurpassed sensitivity and specificity which allows accurate quantitation of viral titer and detection of pathogens within hours. The highly accurate multiplex, parellel testing and quantification system solution ensures cost- and time-effectiveness to laboratories.


Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG)

The abTESTM CT/NG qPCR I Kit utilizes real-time PCR technology to detect and differentiate Chlamydia trachomatis and Neisseria gonorrhoeae in a single reaction tube. This multiplex kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis


Ordering Information

 Product Name   No of Reactions  Detection of   PCR Platform  

  Cat No  

  abTESTM CT/NG qPCR I Kit   50   C.trachomatis and N.gonorrhoeae with IC    
300215

 






Real-time PCR Platforms

       Bio-Rad CFX 96TM     
     Qiagen Rotor-GeneTM A 5/6plex    

Human Immunodeficiency Virus-1 (HIV)

The RealStar® HIV RT-PCR Kit utilizes real-time PCR technology to detect and quantify human immune deficiency virus (HIV) in clinical samples. This kit uses Internal control to monitor the sample extraction efficiency and potential PCR inhibitions.The quantification standards are calibrated against the 1st International Standard for HIV-1 RNA,NIBSC code 97/656 and can be used as positive control for quantitative detection of HIV.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HIV groups M, N and O


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® HIV RT-PCR Kit 1.0  96 Human Immunodeficiency Virus-1 with IC       
221003

 





Real-time PCR Platforms

 
   Life Tech ABI 7500/7500 Fast    
       Abbott m2000rt       
 Corbett Research 
    Rotor-GeneTM 3000/6000   
     Qiagen Rotor-GeneTM   
Q 5-6plex
   Siemens VERSANTTM kPC  
Molecular System

Hepatitis B Virus (HBV)

The abTESTM HBV qPCR I Kit utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clincal sample. This kit uses Internal Control to monitor the sample extraction efficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as positive control for qualitative detection of HBV.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Validated linear range up to 9 orders of magnitude
- Able to detect HBV genotypes from A to H


Ordering Information

 Product Name   No of Reactions  Detection of   PCR Platform  

  Cat No  

 abTESTM HBV qPCR I Kit  50Hepatitis B Virus with IC 
(Quantitative) 
  
300211

 






Real-time PCR Platforms

  Life Tech ABI 7500/7500 Fast  
  Qiagen Rotor-GeneTM A 5/6plex 

Hepatitis B Virus (HBV)

The RealStar® HBV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as posititve control for qualitative detection of HBV.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HBV genotypes from A to H


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® HBV RT-PCR Kit 1.0  96   Hepatitis B Virus with IC       
201003

 





Real-time PCR Platforms

 
   Life Tech ABI 7500/7500 Fast    
       Abbott m2000rt       
 Corbett Research 
    Rotor-GeneTM 3000/6000   
     Qiagen Rotor-GeneTM   
Q 5-6plex
   Siemens VERSANTTM kPC  
Molecular System

Hepatitis C Virus (HCV)

The RealStar® HCV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis C virus (HCV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO International Standard for HCV RNA, NIBSC code 96/798 and can be used as positive control for qualitative detection of HCV.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HCV 1a,1b,2a,2b,2c,2i,3a,4d,5a and 6e


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® HCV RT-PCR Kit 1.0  96   Hepatitis C Virus with IC       
211003

 





Real-time PCR Platforms

 
   Life Tech ABI 7500/7500 Fast    
       Abbott m2000rt       
 Corbett Research 
    Rotor-GeneTM 3000/6000   
     Qiagen Rotor-GeneTM   
Q 5-6plex
   Siemens VERSANTTM kPC  
Molecular System

Hepatitis A Virus (HAV)

The RealStar® HAV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name No of Reactions Detection of   PCR Platform  

  Cat No  

 RealStar® HAV RT-PCR Kit 1.0  96   Hepatitis A Virus with IC          
241013

 

 




Real-time PCR Platforms

 Bio-Rad CFX 96TM 
 Life Tech ABI 7500/7500 Fast 
 Abbott m2000rt 
      Corbett Research Rotor-GeneTM 3000/6000             Qiagen Rotor-GeneTM Q 5/6plex               Siemens VERSANTTM kPCR Molecular System   

Hepatitis E Virus (HEV)

The RealStar® HEV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in a single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name No of Reactions Detection of   PCR Platform  

  Cat No  

 RealStar® HEV RT-PCR Kit 1.0  96   Hepatitis E Virus with IC          
271013

 

 




Real-time PCR Platforms

 Bio-Rad CFX 96TM 
 Life Tech ABI 7500/7500 Fast 
 Abbott m2000rt 
      Corbett Research Rotor-GeneTM 3000/6000             Qiagen Rotor-GeneTM Q 5/6plex               Siemens VERSANTTM kPCR Molecular System