Sexually Transmitted Diseases
There are numbers of sexual transmitted diseases caused by various bacteria and virus namely Chlamydia trachomatis, Neisseria gonorrhea and HIV. The conventional detection method involves viral and bacterial culture, serology test and enzyme-linked immuno assay (ELISA) which are labour-intensive and time consuming. A rapid and precise detection assay is therefore crucial for determination of the infectious pathogen in various samples such as blood, vesicles and pus for effective management of patients. AITbiotech's solution using real-time PCR technology offers unsurpassed sensitivity and specificity which allows accurate quantitation of viral titer and detection of pathogens within hours. The highly accurate multiplex, parellel testing and quantification system solution ensures cost- and time-effectiveness to laboratories.
Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) The abTESTM CT/NG qPCR I Kit utilizes real-time PCR technology to detect and differentiate Chlamydia trachomatis and Neisseria gonorrhoeae in a single reaction tube. This multiplex kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| abTESTM CT/NG qPCR I Kit | 50 | C.trachomatis and N.gonorrhoeae with IC | 300215 |
Real-time PCR Platforms
![]() | ![]() |
| | |
Human Immunodeficiency Virus-1 (HIV) The RealStar® HIV RT-PCR Kit utilizes real-time PCR technology to detect and quantify human immune deficiency virus (HIV) in clinical samples. This kit uses Internal control to monitor the sample extraction efficiency and potential PCR inhibitions.The quantification standards are calibrated against the 1st International Standard for HIV-1 RNA,NIBSC code 97/656 and can be used as positive control for quantitative detection of HIV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HIV groups M, N and O
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HIV RT-PCR Kit 1.0 | 96 | Human Immunodeficiency Virus-1 with IC | 221003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis B Virus (HBV) The abTESTM HBV qPCR I Kit utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clincal sample. This kit uses Internal Control to monitor the sample extraction efficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as positive control for qualitative detection of HBV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Validated linear range up to 9 orders of magnitude
- Able to detect HBV genotypes from A to H
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| abTESTM HBV qPCR I Kit | 50 | Hepatitis B Virus with IC (Quantitative) | | 300211 |
Real-time PCR Platforms
![]() | ![]() |
| | |
Hepatitis B Virus (HBV) The RealStar® HBV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as posititve control for qualitative detection of HBV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HBV genotypes from A to H
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HBV RT-PCR Kit 1.0 | 96 | Hepatitis B Virus with IC | 201003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis C Virus (HCV) The RealStar® HCV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis C virus (HCV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO International Standard for HCV RNA, NIBSC code 96/798 and can be used as positive control for qualitative detection of HCV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HCV 1a,1b,2a,2b,2c,2i,3a,4d,5a and 6e
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HCV RT-PCR Kit 1.0 | 96 | Hepatitis C Virus with IC | 211003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis A Virus (HAV) The RealStar® HAV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HAV RT-PCR Kit 1.0 | 96 | Hepatitis A Virus with IC | | 241013 |
Real-time PCR Platforms
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
| | | |
Hepatitis E Virus (HEV) The RealStar® HEV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in a single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HEV RT-PCR Kit 1.0 | 96 | Hepatitis E Virus with IC | | 271013 |
Real-time PCR Platforms
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
| | | |








