Molecular Diagnostics  Oligonucleotides Synthesis  Capillary Sequencing  Next-Generation Sequencing  Bioinformatics Analysis 

Respiratory Diseases

Respiratory infections can be caused by various viruses. It is a contagious illness that can affect respiratory tract and cause clinical symptoms such as cold and cough. It can also cause severe illness and life-threatening complications in population. Conventional detection method involves viral culture, antigen captured enzyme-linked immuno assay (ELISA) and direct fluorescent antigen (DFA) which are laborious and time consuming. AITbiotech's solution using real-time PCR technology offers unsurpassed sensitivity and specificity which allows accurate detection of pathogens within hours. The highly accurate multiplex AITbiotech's solution ensures cost- and time-effectiveness to laboratories.


Influenza Virus

The abTESTM Flu qPCR Kit utilizes real-time PCR technology to detect and differentiate human Influenza A and Influenza B, and are able to subtype swine H1, human seasonal H1 and human seasonal H3 strains in a single reaction tube. This multiplex kit is designed to fullfil WHO parameters for surveillance and monitoring of Influenza outbreak worldwide.

Specifications
- Turnaround time of 3 hours from sample to result
- Data fulfill WHO parameters for surveillance and monitoring of Influenza outbreak
- Easy reaction setup and result analysis
- Compatible with various real-time PCR platfroms
- Multiplex and sensitive detection of Influenza virus with updated probe and primers sets


Ordering Information

Product Name No of Reactions Detection of PCR Platform

Cat No

abTESTM Flu 5 qPCR I Kit50
100
FluA/FluB/swH1N1/huH1N1/huH3N2
300101
 300102 
abTESTM Flu 5 qPCR II Kit
50
100
FluA/FluB/swH1N1/huH1N1/huH3N2
300103
300104
abTESTM Flu 4 qPCR I Kit50
100
FluA/FluB/swH1N1/huH1N1/huH3N2 with IC 300105
300106
abTESTM Flu 4 qPCR I Kit50
100 
FluA/FluB/swH1N1/huH1N1/huH3N2 with GAPDH 300107
300108
abTESTM Flu 4 qPCR V Kit 50
100
FluA/FluB/swH1N1/huH3N2
300113
300114
abTESTM Flu 2 qPCR I Kit50
100
FluA/swH1N1 with GAPDH as IC 300117
300118
abTESTM Flu 2 qPCR I Kit 50
100
FluA/Avian H5N1 with IC 
300121
300122
abTESTM Flu qPCR I Kit 50
100 
Avian H5N1 with IC  
300123
300124

 

 

 

 

 

 

 

 

 

 

 

 



Real-time PCR Platforms

        Bio-Rad CFX 96TM                      Stratagene Mx 3005PTM     
        Qiagen Rotor GeneTM Q 5/6plex      

Influenza Virus

The RealStar® Influenza RT-PCR Kit utilizes real-time PCR technology to detect and differentiate human Influenza A, Influenza B and SwineH1N1 in a single reaction tube. This ready-to-use kit comes with internal control to monitor sample extraction efficiency and possible PCR inhibitors.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Compatible with various real-time PCR platforms
- Parellel testing within respiratory RT-PCR test kit panel 



Ordering Information

Product Name No of Reactions Detection of PCR Platform

Cat No 

 RealStar® Influenza S & T RT-PCR Kit 2.0 96

 Influenza A/B and SwineFlu (H1N1) 

         162013
RealStar® Influenza S & T RT-PCR Kit 3.0 96

Influenza A/B and SwineFlu (H1N1)

         163013

 








Real-time PCR Platforms

 Bio-Rad CFX 96TM
 Stratagene Mx3005PTM
 Life Tech ABI 7500/7500 Fast
 Abbott m2000rt

 Corbett Research Rotor-GeneTM 3000/6000 Qiagen Rotor-GeneTM Q 5/6plexSiemens VERSANTTM kPCR Molecular System

  Roche LightCycler® Instrument 480 II

Metapneumovirus (MPV)

The RealStar® hMPV RT-PCR Kit utilizes real-time PCR technology to detect human metapneumovirus (MPV), and is able to subtype MPV A and MPV B in a single reaction tube. This multiplexe kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical respiratory samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® hMPV RT-PCR Kit 1.0 96 Human Metapneumovirus        
251013

 

 



Real-time PCR Platforms

 Bio-Rad CFX 96TM 
 Life Tech ABI 7500/7500 Fast 
 Abbott m2000rt 
      Corbett Research Rotor-GeneTM 3000/6000             Qiagen Rotor-GeneTM Q 5/6plex               Siemens VERSANTTM kPCR Molecular System   

Parainfluenza Virus (PIV)

The RealStar® PIV RT-PCR Kit utilizes real-time PCR technology to detect and quantify human parainfluenza virus (PIV), and is able to subtype PIV 1 and PIV 3 from PIV 2 and PIV 4 in a single reaction tube. This multiplex kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and realiable tool for screening of clinical respiratory samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® PIV RT-PCR Kit 1.0  96 Human Parainfluenza 1-4 Virus with IC       
261013

 





Real-time PCR Platforms

 
   Life Tech ABI 7500/7500 Fast    
       Abbott m2000rt       
 Corbett Research 
    Rotor-GeneTM 3000/6000   
     Qiagen Rotor-GeneTM  
Q 5-6plex
   Siemens VERSANTTM kPC  
Molecular System

Respiratory Syncytical Virus (RSV)

The RealStar® RSV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect Respiratory Syncytical Virus (RSV) , and is able to subtype RSV A and RSV B in a single reaction tube. This multiplex kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical respiratory samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name No of Reactions Detection of  PCR Platform 

 Cat No 

 RealStar® RSV RT-PCR Kit 1.0 96 Respiratory Syncytical Virus A and B with IC     
191013

 





Real-time PCR Platforms

 
   Life Tech ABI 7500/7500 Fast    
       Abbott m2000rt       
 Corbett Research 
    Rotor-GeneTM 3000/6000   
     Qiagen Rotor-GeneTM   
Q 5-6plex
   Siemens VERSANTTM kPC  
Molecular System

Adenovirus (hAdV)

The RealStar® Adenovirus PCR Kit 1.0 utilizes real-time PCR technology for detection and quantification of human Adenovirus (hAdV) DNA. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of human respiratory samples.

Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening


Ordering Information

Product Name   No of Reactions  Detection of PCR Platform

 Cat No 

   RealStar® Adenovirus PCR Kit 1.0   96

   Adenovirus with IC   
(Quantitative) 

             
  301013  

 







Real-time PCR Platforms

 Bio-Rad CFX 96TM
 Stratagene Mx3005PTM
 Life Tech ABI 7500/7500 Fast
 Abbott m2000rt

 Corbett Research Rotor-GeneTM 3000/6000 Qiagen Rotor-GeneTM Q 5/6plex Siemens VERSANTTM kPCR Molecular System

  Roche LightCycler® Instrument 480 II