Blood-borne Diseases
The precise detection and quantification of blood borne viruses such as HBV, HCV, HIV and Parvo B19 is crucial for apporapriate patient management and for the control of the viral transmission in the population. Conventional detection methods such as enzyme-link immune assay (ELISA) and antigen-antibody testing are labour-intensive and time consuming. End-point gel based PCR or reverse-transcription PCR are lacking of quantitative accuracy. AITbiotech's solution using real-time PCR technology offers unsurpassed sensitivity and specificity which allows accurate quantitation of viral titer within hours. The highly accurate parellel testing and quatification system ensures cost- and time-effectiveness to laboratories.
Human Immunodeficiency Virus-1 (HIV) The RealStar® HIV RT-PCR Kit utilizes real-time PCR technology to detect and quantify human immune deficiency virus (HIV) in clinical samples. This kit uses Internal control to monitor the sample extraction efficiency and potential PCR inhibitions.The quantification standards are calibrated against the 1st International Standard for HIV-1 RNA,NIBSC code 97/656 and can be used as positive control for quantitative detection of HIV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HIV groups M, N and O
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HIV RT-PCR Kit 1.0 | 96 | Human Immunodeficiency Virus-1 with IC | 221003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis B Virus (HBV) The abTESTM HBV qPCR I Kit utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clincal sample. This kit uses Internal Control to monitor the sample extraction efficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as positive control for qualitative detection of HBV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Validated linear range up to 9 orders of magnitude
- Able to detect HBV genotypes from A to H
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| abTESTM HBV qPCR I Kit | 50 | Hepatitis B Virus with IC (Quantitative) | | 300211 |
Real-time PCR Platforms
![]() | ![]() |
| | |
Hepatitis B Virus (HBV) The RealStar® HBV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis B virus (HBV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO HBV International Standard for NAT Testing 97/746 and can be used as posititve control for qualitative detection of HBV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HBV genotypes from A to H
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HBV RT-PCR Kit 1.0 | 96 | Hepatitis B Virus with IC | 201003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis C Virus (HCV) The RealStar® HCV PCR Kit 1.0 utilizes real-time PCR technology to detect and quantify hepatitis C virus (HCV) in clinical sample. This kit uses Internal Control to monitor the sample extraction effficiency and potential PCR inhibitions. The quantification standards are calibrated against the WHO International Standard for HCV RNA, NIBSC code 96/798 and can be used as positive control for qualitative detection of HCV. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect HCV 1a,1b,2a,2b,2c,2i,3a,4d,5a and 6e
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HCV RT-PCR Kit 1.0 | 96 | Hepatitis C Virus with IC | 211003 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() | ![]() |
| | | Rotor-GeneTM 3000/6000 | Q 5-6plex | Molecular System |
Hepatitis A Virus (HAV) The RealStar® HAV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HAV RT-PCR Kit 1.0 | 96 | Hepatitis A Virus with IC | | 241013 |
Real-time PCR Platforms
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
| | | |
Hepatitis E Virus (HEV) The RealStar® HEV RT-PCR Kit 1.0 utilizes real-time PCR technology to detect hepatitis A virus in a single reaction tube. This kit uses Internal Control to monitor the sample extraction process and potential PCR inhibitions. The kit is a rapid and reliable tool for screening of clinical samples. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Easy reaction setup and result analysis
- Tailored solution for routine laboratory screening
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® HEV RT-PCR Kit 1.0 | 96 | Hepatitis E Virus with IC | | 271013 |
Real-time PCR Platforms
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
| | | |
Parvo B19 The RealStar® Parvovirus B19 PCR Kit utilizes real-time PCR technology to detect and quantify Parvo B19 virus in clinical sample. This kit uses Internal Control to monitor the sample extraction efficiency and potential PCR inhibitions. The quantification standards are calibrated against 2nd WHO International Standard for Parvovirus B19 (NIBSC code: 99/802) and can sed used as positive control for qualitative detection of Parvovirus B19. |
|
Specifications
- Turnaround time of 3 hours from sample to result
- Includes an Internal Control to monitor sample extraction efficiency and potential PCR inhibitions
- Able to detect 3 distinct genotypes of Parvovirus B19
Ordering Information
| Product Name | No of Reactions | Detection of | PCR Platform | Cat No |
| RealStar® Parvovirus B19 PCR Kit 1.0 | 96 | Parvovirus B19 Virus with IC | 101013 | |
| RealStar® Parvovirus B19 PCR Kit 1.2 | 96 | Parvovirus B19 Virus with IC | 101012 |
Real-time PCR Platforms
![]() | ![]() | ![]() | ![]() |
| | | ||
![]() | ![]() | ![]() | |
|